Auto Transfer Switch Control Module

The DSE335 Automatic Transfer Switch Control Module has been expertly developed to monitor the voltage and frequency of an incoming AC supply from two different sources. These sources can be generator or mains (utility), or a combination of both. The control module monitors Source 1 (S1) and Source 2(S2). When a failure occurs a start command is issued to the inactive source to take over the load. The module will return the load to the mains (utility) as soon as this becomes available.

OVERALL SIZE
240 mm x 181 mm x 42 mm (9.4” x 7.1” x 1.6”)
PANEL CUTOUT SIZE
220 mm x 160 mm (8.7” x 6.3”)
MAXIMUM PANEL THICKNESS
8.0mm (0.3”)
WEIGHT
0.9kg
PRODUCT VARIANTS
0335-01 – 335 Auto Transfer Switch Control Module – 12/24 Volt DC Supply

 

SKU: DSE334 Category:

Description

Product Highlights
Key Features Key Benefits
Automatic switch over between supplies. Switches power when mains (utility) supply fails and switches back when mains (utility) supply returns.
Manual restore to S1. Allows flexible control of source inputs.
Configurable inputs/outputs (10/5). Provides multiple installation options.
Optional current monitoring. Provides accurate information on over and under current conditions.
Source 1/source 2 control. Allows flexible control of source inputs.
Check sync feature. Ensures the smoothest possible transfer is achieved.
Compatible with DSE160 power supply. When no DC supply is available the DSE160 power supply connects to an AC power supply and then to the control module.
DSE Configuration Suite PC Software. Provides complete user-friendly configuration and easy-to-use high-level system control & monitoring.
Configurable event log (10). Provides access to historical alarms and operational status.
Additional Features
  • Volt-free relays.
  • Multiple topology support.
  • Configurable timers.
  • Front panel configuration.
  • LED indicators.
  • External mains (utility) or genset failure inputs.
  • Auto start inhibit.
  • Load inhibit.

Specification

DC SUPPLY

CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous

CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.

MAXIMUM OPERATING CURRENT
292 mA at 12 V, 167 mA at 24 V

MAXIMUM STANDBY CURRENT
101 mA at 12 V, 66 mA at 24 V

MAINS (UTILITY)

VOLTAGE RANGE
15 V to 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz

OUTPUTS

OUTPUT A (MAINS/UTILITY/S1)
Normally closed volt-free output 8 A AC at 250 V AC

OUTPUT B (GENERATOR/S2)
Normally open volt-free output 8 A AC at 250 V AC

OUTPUT C (START AND RUN)
Normally closed volt-free output 8 A DC at 35 V DC (UL Rating 30 V)

OUTPUT D
Changeover volt-free output 8 A AC at 250 V AC

OUTPUT E
Normally open volt-free output 8 A AC at 250 V AC

GENERATOR

VOLTAGE RANGE
15 V to 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz